Roofers use a circular saw to cut a long slot along the roof ridge if there isn t one then cover it with a plastic flap as shown or a flexible vinyl matrix.
Warm roof no ventilation.
Worse yet inadequate insulation is almost surely allowing moisture laden air into your attic.
The building envelope is tight enough to prevent warm moist air from escaping from the building interior into the roof assembly.
The article notes that the ventilation cannot overcome the significant humidity drive into the flat roof structure caused by small air leaks.
An unvented roof assembly is possible only if you keep the roof sheathing warm enough to prevent conditioned air from condensing against it.
When the condensation forms on the roof deck it begins to rot the wood.
No ventilation is required for these types of roofs.
I am about to turn my garage flat roof into a warm roof i have a seperate thread discussing this task in the roofing section with the primary goal of having no ventilation whatsoever as i will be building a decoupled room inside this sealed garage shell to use as a music recording studio so every single hole becomes a compromise for sound isolation.
Warm roof ventilation specification for a simple duo pitch roof bs 5250 specifies sufficient ventilation as being.
Venting prolongs the life of the roof.
There is enough exit ventilation space to match the amount of soffit ventilation inlet.
This moisture is released into the air inside the house from bathing cooking plants laundry and other causes.
Openings along the sides allow air out of the attic cooling the space and lowering your air conditioning bill.
Consequently the article concludes that the concept of venting a flat roof is no longer safe and instead don t vent the flat roof and install a smart vapor retarder inboard.
If ridge or eaves ventilation is not possible ventilation tiles can be used at high or low level to achieve the required airflow.
25mm at eaves on each slope and 5mm at ridge.
Unless your roofing system has insulation on the roofing deck and is designed without ventilation your furnace should not be heating your attic.
In buildings where there is no roof venting anyway and where ventilation is difficult or impossible to achieve an un vented well insulated hot roof can provide a high r value ceiling and may be the second best alternative to preventing ice dam related leaks in cold climates.
Without adequate ventilation moisture rises with the hot air and forms condensation on the inside of the roof deck.